List/Grid

Cables Feat Subscribe to Cables Feat

N2XSY/NA2XSY/N2XCY NA2XCY

N2XSY/NA2XSY/N2XCY NA2XCY

Applications: Single core power cable, copper or aluminium conductor, XLPE insulated with or without blocking water tape, copper wire or copper tape screened, PVC sheathed. Use for indoor or outdoor… Read more »

N2XSEY/NA2XSEY

N2XSEY/NA2XSEY

Applications: Copper or aluminium conductor, XLPE insulated with or without water blocking tape, copper tape screened, PVC sheathed. Use for indoor or outdoor installation in conduit, trays or in the… Read more »

N2XSEBY/NA2XSEBY

N2XSEBY/NA2XSEBY

Applications: Copper or aluminium conductor, XLPE insulated, copper tape screened, double steel tapes armoured and PVC sheathed. Suitable for distribution indoor and outdoor installation, direct burial oron trays. Specifications: IEC… Read more »

NYYHY – 0 (1)  450/750 VOLT

NYYHY – 0 (1) 450/750 VOLT

These low voltage flexible cables are applied for appliances Construction Conductor or stranded annealed copper conductor Insulation Extruded colored PVC, capable for the operating continuously maximum temperature of the cable… Read more »

NYFGbY, NYRGbY, NAYFGbY, NAYRGbY 0 (1) 0.6/1 kV

NYFGbY, NYRGbY, NAYFGbY, NAYRGbY 0 (1) 0.6/1 kV

These low voltage cables are applied for common indoor Construction NYFGbY & NYRGbY : solid, stranded or sectoral shape annealed copper conductor NAYFGbY & NAYRGbY: s olid, stranded or sectoral… Read more »

NYM – 0 (1) 300/500 VOLT

NYM – 0 (1) 300/500 VOLT

These low voltage cables are applied for common indoor installation but not underground. Construction Conductor or stranded annealed copper conductor Insulation Extruded colored PVC, capable for the operating continuously maximum temperature of… Read more »

NYY – 0 (1) 0.6/1 kV

NYY – 0 (1) 0.6/1 kV

These low voltage cables are applied for common indoor Construction Conductor or stranded annealed copper conductor Insulation Extruded colored PVC, capable for the operating continuously Inner Sheath Extruded black PVC… Read more »

NYMHY – 0 (1)  300/500 VOLT

NYMHY – 0 (1) 300/500 VOLT

  These low voltage flexible cables are applied for stresses and heating appliance in dry rooms and household appliances in humid rooms. Construction Conductor or stranded annealed copper conductor Insulation… Read more »

NYAF – 0 (1)  450/750 VOLT

NYAF – 0 (1) 450/750 VOLT

  These low voltage flexible cables are applied for instead of NYA cable. Construction Conductor or stranded annealed copper conductor Insulation Extruded colored PVC, capable for the operating continuously maximum… Read more »

NYA – 0 (1)  450/750 VOLT

NYA – 0 (1) 450/750 VOLT

  Construction Solid or stranded annealed copper conductor Insulation Extruded colored PVC, capable for the Sheath Extruded white PVC suitable for the operating temperature of the cable cables are applied… Read more »